Hy1000Ex

1,000 L custom solvent recovery system

Automatic replenishment supports continuous-feed distillation. A water-cooled condenser collects recovered solvent for evaluation and reuse. Choose a single unit or discuss a linked installation.

Single Hy1000Ex solvent recovery system with a yellow-railed platform, stairs and ancillary equipment
Single-unit example with an operator access platform.
Working capacity
1,000 L
Reference throughput
200–250 L/h
Maximum heating power
66 kW

Reference specifications

For one thermal-oil-heated unit. Final equipment, utilities and layout are specified for each project.

Hy1000Ex thermal-oil configuration
SpecificationReference value
Working capacity1,000 L
Total vessel volume1,300 L
Throughput200–250 L/h with continuous feed. Actual rate depends on the feed and operating conditions. Daily volume also depends on heating, cooling, cleaning and residue removal time.
Distillation vesselSUS304 stainless steel, 8 mm wall, triple-wall welded construction and mirror-finished interior
Lid and sealDual-flange lid with moulded PTFE gasket
Heat sourceIndirect thermal-oil circulation. Alternative steam-heated configuration available.
Heating and circulation66 kW maximum heating power. 5.5 kW thermal-oil circulation pump and OMRON temperature control. Confirm total electrical load for the selected configuration.
CondenserWater-cooled 316L stainless steel spiral-wound shell-and-tube condenser, 8 m² heat-transfer area
Cooling-water supply10–20 °C reference inlet. Flow and cooling duty depend on the application.
Automatic feedPneumatic diaphragm pump, feed valve and dual level control
ControlsMicrocontroller, OMRON temperature control and programmable six-stage time and temperature profile
Residue outletBottom outlet with pneumatic valve and manual backup
Electrical supply380 V or 415 V selectable at order. Three-phase, 50/60 Hz reference. Confirm the plant supply and total connected load for the project.
Compressed air0.4–0.6 MPa, clean and dry
Main-unit dimensions3,246 × 1,866 × 3,311 mm (L × W × H)
Net weightApprox. 3,500 kg
Layout allowance6 × 8 m per unit as a planning reference. Confirm access, tanks, utilities and clearances on the final layout.

Configure the system for your plant

Hy1000Ex project options
OptionWhat can be specified
Liquid-ring vacuumElectric liquid-ring unit with cooling and support equipment sized to the application
Steam heatingAlternative heating package where suitable plant steam is available
Agitator or wall scraperPTFE-coated agitator or wall scraper selected for the feed and residue
Rapid thermal-oil coolingAdditional cooling module for the thermal-oil configuration
Automatic residue dischargeAutomatic valve sequencing for suitable flowable residues and collection arrangements
Residue weighingWeighed collection with a configured stop and alarm limit
Siemens or Mitsubishi PLCColour HMI, alarm history and project-specific diagnostics
Remote monitoring and controlMonitoring interfaces and control functions defined for the site
Ambient solvent vapour detectionOptional area monitoring and alarms
Premium level sensorsAlternative sensor technologies for demanding process conditions
Waste and recovered solvent tanksStandalone or interlocked tanks sized for the project
Industrial water chillerSeparate chilled-water supply sized for the condenser and selected vacuum equipment

Monitoring and protective interlocks

In the thermal-oil reference configuration, the controls monitor pressure, temperature, cooling and feed level. Confirm the agreed protection functions and equipment documentation for your installation.

Pressure monitoring

The pressure transmitter is linked to a protective heating stop. The system also includes mechanical pressure relief.

Over-temperature protection

The thermal-oil system includes an over-temperature main-breaker trip.

Condenser monitoring

Loss of cooling or excessive condensate temperature can trigger a protective heating stop and alarm.