Pressure monitoring
The pressure transmitter is linked to a protective heating stop. The system also includes mechanical pressure relief.
Automatic replenishment supports continuous-feed distillation. A water-cooled condenser collects recovered solvent for evaluation and reuse. Choose a single unit or discuss a linked installation.
For one thermal-oil-heated unit. Final equipment, utilities and layout are specified for each project.
| Specification | Reference value |
|---|---|
| Working capacity | 1,000 L |
| Total vessel volume | 1,300 L |
| Throughput | 200–250 L/h with continuous feed. Actual rate depends on the feed and operating conditions. Daily volume also depends on heating, cooling, cleaning and residue removal time. |
| Distillation vessel | SUS304 stainless steel, 8 mm wall, triple-wall welded construction and mirror-finished interior |
| Lid and seal | Dual-flange lid with moulded PTFE gasket |
| Heat source | Indirect thermal-oil circulation. Alternative steam-heated configuration available. |
| Heating and circulation | 66 kW maximum heating power. 5.5 kW thermal-oil circulation pump and OMRON temperature control. Confirm total electrical load for the selected configuration. |
| Condenser | Water-cooled 316L stainless steel spiral-wound shell-and-tube condenser, 8 m² heat-transfer area |
| Cooling-water supply | 10–20 °C reference inlet. Flow and cooling duty depend on the application. |
| Automatic feed | Pneumatic diaphragm pump, feed valve and dual level control |
| Controls | Microcontroller, OMRON temperature control and programmable six-stage time and temperature profile |
| Residue outlet | Bottom outlet with pneumatic valve and manual backup |
| Electrical supply | 380 V or 415 V selectable at order. Three-phase, 50/60 Hz reference. Confirm the plant supply and total connected load for the project. |
| Compressed air | 0.4–0.6 MPa, clean and dry |
| Main-unit dimensions | 3,246 × 1,866 × 3,311 mm (L × W × H) |
| Net weight | Approx. 3,500 kg |
| Layout allowance | 6 × 8 m per unit as a planning reference. Confirm access, tanks, utilities and clearances on the final layout. |
| Option | What can be specified |
|---|---|
| Liquid-ring vacuum | Electric liquid-ring unit with cooling and support equipment sized to the application |
| Steam heating | Alternative heating package where suitable plant steam is available |
| Agitator or wall scraper | PTFE-coated agitator or wall scraper selected for the feed and residue |
| Rapid thermal-oil cooling | Additional cooling module for the thermal-oil configuration |
| Automatic residue discharge | Automatic valve sequencing for suitable flowable residues and collection arrangements |
| Residue weighing | Weighed collection with a configured stop and alarm limit |
| Siemens or Mitsubishi PLC | Colour HMI, alarm history and project-specific diagnostics |
| Remote monitoring and control | Monitoring interfaces and control functions defined for the site |
| Ambient solvent vapour detection | Optional area monitoring and alarms |
| Premium level sensors | Alternative sensor technologies for demanding process conditions |
| Waste and recovered solvent tanks | Standalone or interlocked tanks sized for the project |
| Industrial water chiller | Separate chilled-water supply sized for the condenser and selected vacuum equipment |
In the thermal-oil reference configuration, the controls monitor pressure, temperature, cooling and feed level. Confirm the agreed protection functions and equipment documentation for your installation.
The pressure transmitter is linked to a protective heating stop. The system also includes mechanical pressure relief.
The thermal-oil system includes an over-temperature main-breaker trip.
Loss of cooling or excessive condensate temperature can trigger a protective heating stop and alarm.
Discuss a single unit or a shared-inlet and shared-outlet arrangement. Up to five units can be reviewed for linked installations. We assess available space, utility demand, access and combined throughput for each project.



Tell us about your solvent, daily volume, reuse target and plant location. HY Environment will discuss the equipment configuration, site preparation, commissioning, operator training and after-sales arrangements.